High-capacity Surron and Talaria battery upgrades need more than a generic power supply. They need a charger configured around the battery's voltage, chemistry, current limits, connector and intended operating environment.
The TRB POWER Apex CH30 Ultra is a fully digital smart lithium battery charger developed for professionally matched battery systems, including compatible Surron and Talaria battery projects. It combines configurable charging parameters, up to 2.3kW total output power, wide-range AC input, high conversion efficiency, real-time charging information and integrated protection functions in a durable aluminum enclosure.
It is designed for Surron and Talaria riders, performance builders, dealers and battery specialists who need a more capable charging platform for high-capacity electric motorcycle and e-moto batteries.
The Apex CH30 Ultra is not a universal plug-and-play charger for every Surron or Talaria model. Battery type, charging voltage, current setting, connector, polarity and regional electrical requirements must be confirmed before production or use.
Apex CH30 Ultra Specifications at a Glance
| Item | Specification |
|---|---|
| Product | TRB POWER Apex CH30 Ultra |
| Charger type | Fully digital smart lithium battery charger |
| Intended battery range | 30-98V lithium battery packs |
| AC input | 100-240V AC, 47-65Hz, single phase |
| Configurable current setting | 5-50A, configured for the battery application |
| Main charging current range | 16-50A |
| Pre-charge current | 10A |
| Total output power | Up to 2300W |
| Maximum efficiency | Up to 94% at 110V AC; up to 97% at 240V AC |
| Maximum measured ripple | 400mV peak-to-peak under the specified test method |
| Cooling | Fan convection |
| Operating temperature | -20 to +50 degrees C |
| Storage temperature | -20 to +65 degrees C |
| Protection functions | Short circuit, overcurrent, input over/undervoltage, overtemperature and reverse-battery-related protection requirements |
Specifications are based on the Apex CH30 Ultra technical specification, REV.001, issued May 25, 2026. Final parameters and compliance requirements depend on the confirmed battery application, destination market and production configuration.
A Configurable Charging Platform
The most important feature of the Apex CH30 Ultra is not one fixed voltage or current figure. It is the ability to configure the charging parameters around a specific lithium battery.
The technical platform is developed for lithium battery packs in the 30-98V range, with configurable charging-current settings from 5A to 50A. The main charging stage supports 16-50A, while a 10A pre-charge stage is specified for the appropriate charging sequence.
This flexibility allows TRB POWER to prepare the charger for different battery architectures, but the settings must never be changed by guesswork. The following information should be confirmed before the charger is configured:
- Battery chemistry
- Series configuration
- Nominal battery voltage
- Maximum charge voltage
- Recommended and maximum charge current
- Battery-management-system limits
- Main connector and polarity
- Signal or communication requirements
- Destination-market AC plug
- Intended operating environment
A charger can only be considered compatible when the battery and charger specifications agree across the complete interface.
Up to 2.3kW for High-Capacity Battery Systems
The Apex CH30 Ultra provides up to 2300W of total output power. This gives it the capacity to support faster charging workflows than many lower-power portable chargers when it is correctly matched to the battery.
Charging time, however, cannot be calculated from charger power alone. It also depends on:
- Usable battery energy
- Battery state of charge
- Configured charging current
- Constant-current and constant-voltage stages
- BMS limits
- Cell temperature
- Battery condition
- AC input capacity
For example, a high-capacity battery may accept a strong charging current during the main constant-current stage, then gradually reduce current as it approaches full charge. The final portion of the charging cycle can therefore take proportionally longer.
TRB POWER should calculate the appropriate charger configuration from the actual battery specification rather than promising one universal charging time.
Wide-Range 100-240V AC Input
The Apex CH30 Ultra supports single-phase AC input from 100V to 240V at 47-65Hz. This makes the platform suitable for configuration across multiple destination markets.
The AC supply, wall circuit, cable and plug still need to be rated for the final charger configuration. High-power charging places a meaningful load on the mains supply. Users should verify the available circuit capacity and follow local electrical requirements before operation.
Regional plug type and final compliance requirements should be confirmed when ordering.
High Conversion Efficiency
Under the specified maximum-output-load test conditions, the Apex CH30 Ultra reaches:
- Up to 94% maximum efficiency at 110V AC input
- Up to 97% maximum efficiency at 240V AC input
Higher conversion efficiency means more of the incoming electrical energy is delivered to the charging process and less is lost as heat. It also supports more controlled operation in a compact high-power charger.
Actual efficiency can vary with input voltage, output voltage, charging current, battery state and temperature.
Real-Time Charging Information
The charger interface is designed to make the charging state easier to understand.
During charging, the display shows real-time current and voltage information. A dynamic circular indicator communicates that charging is active. When the battery reaches the configured full-charge condition, the corresponding indicator stops and the displayed charging time no longer changes.
This gives the user a clearer view of:
- Charging status
- Present charging voltage
- Present charging current
- Charging progress
- Completed-charge state
The display supports monitoring, but it does not replace correct battery configuration or safe charging practices.
Integrated Protection Functions
High-power charging requires coordinated protection. The Apex CH30 Ultra technical design includes the following protection requirements:
Short-Circuit Protection
If an output short circuit occurs during normal operation, the charger enters protection. The fault must be removed and AC input restarted before charging resumes.
Overcurrent Protection
The charger shuts down when an overcurrent condition triggers protection. Operation can resume after the fault is removed and AC input is restarted.
Input Overvoltage and Undervoltage Protection
The charger shuts down when the AC input moves outside the supported operating condition and can recover after the input fault is cleared.
Overtemperature Protection
The output shuts down if the charger exceeds its permitted temperature condition. Charging can recover after the fault is cleared and the temperature returns to an acceptable level.
Reverse-Battery-Related Protection Requirements
The charger must be used with the correct TRB POWER cable and matching factory accessories. Connector type, wiring and polarity must be confirmed before use.
Protection functions reduce risk, but they are not a substitute for correct installation, compatible equipment or supervised charging in a suitable location.
Designed for Demanding Operating Environments
The Apex CH30 Ultra uses fan-convection cooling and is specified for full-load operation from -20 to +50 degrees C, with a relative-humidity range of 20% to 80%.
Its specified storage range is -20 to +65 degrees C without condensation. Operating and non-operating altitude is specified up to 5000m.
For dependable operation:
- Keep the air inlets and outlets unobstructed
- Use the charger on a stable, dry surface
- Keep it away from rain and direct water exposure
- Do not cover the enclosure during charging
- Avoid combustible materials around the charging area
- Inspect cables and connectors before each use
- Stop operation if abnormal heat, smell, sound or damage is observed
Who Is the Apex CH30 Ultra For?
The Apex CH30 Ultra is particularly relevant for:
- Surron owners using professionally configured high-capacity battery upgrades
- Talaria owners using professionally configured high-capacity battery upgrades
- High-performance Surron and Talaria builders
- Workshops supporting multiple battery projects
- Dealers preparing matched battery-and-charger packages
- Battery manufacturers requiring configurable charging parameters
- Fleet or commercial users with documented charging procedures
It is not intended to be selected from nominal voltage alone. Every order should begin with the battery specification.
Information Required Before Ordering
To help TRB POWER prepare the correct charger configuration, provide:
- Vehicle brand, model and production year
- Battery brand and model
- Battery chemistry
- Nominal voltage
- Maximum charge voltage
- Capacity in Ah and Wh
- Recommended and maximum charging current
- BMS charging limit
- Connector photos, pinout and polarity
- Destination country and AC plug type
- Intended use, such as personal riding, workshop, dealer or fleet charging
If the battery specification is incomplete, the charger configuration should not be finalized.
Configure the Apex CH30 Ultra for Your Surron or Talaria Battery
The Apex CH30 Ultra brings high output power, configurable charging control and clear operating information together in one professional lithium battery charger platform for compatible Surron and Talaria battery projects.
Contact TRB POWER with the exact Surron or Talaria model and complete battery specification. The team can review the maximum charge voltage, charging current, connector, polarity and destination-market requirements before confirming the appropriate configuration.
Confirm Your Surron or Talaria Charger Configuration
Frequently Asked Questions
What batteries can the Apex CH30 Ultra charge?
The technical platform is developed for 30-98V lithium battery packs. Compatibility depends on battery chemistry, maximum charge voltage, charging-current limits, connector, polarity and any communication requirements.
Can the Apex CH30 Ultra charge a Surron battery?
It can be configured for compatible Surron battery systems when the exact battery chemistry, maximum charge voltage, charging-current limit, connector, polarity and any communication requirements are confirmed. It should not be treated as universal across all Surron models or aftermarket batteries.
Can the Apex CH30 Ultra charge a Talaria battery?
It can be configured for compatible Talaria battery systems after the complete battery and vehicle information is reviewed. Different Talaria models and aftermarket battery upgrades may require different voltage, current, connector or communication configurations.
Can one charger work with both Surron and Talaria batteries?
Only when both battery systems share the same approved charging voltage, current limit, connector, polarity and required control interface. Similar nominal-voltage labels do not prove compatibility. TRB POWER must confirm the exact combination before use.
Is the charging current adjustable?
The charger supports configurable current settings from 5A to 50A. The production setting must be matched to the battery and confirmed with TRB POWER.
What is the maximum output power?
The specified total output power is up to 2300W.
Can the charger work with both 110V and 240V AC?
The specified AC input range is 100-240V at 47-65Hz. The regional plug, mains-circuit capacity and final compliance configuration must still be confirmed.
How fast will it charge my battery?
Charging time depends on battery energy, state of charge, configured current, BMS limits, temperature and the constant-voltage finishing stage. TRB POWER needs the complete battery specification before estimating charging time.
Can I change the voltage or current settings myself?
Voltage and current parameters must be confirmed with the manufacturer before modification. Incorrect settings can damage the battery, charger or connected equipment.
Does the charger have safety certification?
Certification and compliance requirements depend on the final application, destination market and production configuration. Confirm the required certification status with TRB POWER before ordering.
Technical source: TRB POWER, Battery Charger Technical Specification - Apex CH30 Ultra, REV.001, May 25, 2026.
Compatibility notice: This article does not confirm universal compatibility with any Surron or Talaria model. Final charger settings, connector, polarity, accessories, AC plug and compliance requirements must be approved for the exact vehicle and battery application.